Description
The UVC Ozone Aging Tester evaluates rubber deterioration in an ozone test chamber and to meet the requirement of ISO 1431.
Model PPHM
Model | PPHM-S | PPHM-D | PPHM-SD |
Ozone concentration range | 20 to 200pphm | ||
Temperature range | RT(+10°C) to 40°C | ||
Test method | Static | Static or Dynamic | Static & Dynamic (Dual use) |
Ozone test chamber | W500 × D500 × H500mm | W500 × D500 × H750mm | |
Power supply | Single-phase, AC100V, 50/60Hz, 1.5kVA
(230V or 115V using step-down transformer) |
||
Dimensions | W1110 × D690 × H1700mm | W1110 × D690 × H1950mm | |
Weight (Approx.) | 180kg | 230kg | 240kg |
Model PPM
Model | PPM-S | PPM-D | PPM-SD |
Ozone concentration range |
Two-stage switching |
||
Temperature range | RT(+10°C) to 40°C | ||
Test method | Static | Static or Dynamic | Static & Dynamic (Dual use) |
Ozone test chamber | W500 × D500 × H500mm | W500 × D500 × H750mm | |
Power supply | Single-phase, AC100V, 50/60Hz, 2kVA
(230V or 115V using step-down transformer) |
||
Dimensions | W1110 × D690 × H1700mm | W1110 × D690 × H1950mm | |
Weight (Approx.) | 210kg | 260kg | 330kg |
Related standards
ISO 1431-1 | Rubber, vulcanized or thermoplastic — Resistance to ozone cracking — Part 1: Static and dynamic strain testing |